OMT200  Measuring Moisture in Lubricating Oil

Moisture in Oil and Temperature Transmitter for OEM Application

 

Product Profile

OMT200 is a fast, reliable and accurate online detector for water activity (aw) in oil and temperature (T). Water Activity is a relative parameter for moisture. In some application, it is more obvious than traditional absolute terminology, for it is directly meaning the possibility to happening of water separation. Water formation is often critic accident for processes.

 

0MT200 is ideal for online monitoring of moisture in lubrication, hydraulic or insulation oil, which is very important for the long-term performance and preventive maintenance of power plant and machinery.


Major Features

· Continuous measurement of water activity in oil and temperature

· Professional calculation of moisture content in ppm for transformer oil

· Accurate, reliable and rugged designing under hostile environments

· Convenient local & remote calibration

· Excellent pollution & pressure tolerance

· Compact, easy for integration

· Analog and Digital Signals Output

 

OMT200  Measuring Moisture in Lubricating Oil

Technical Parameter 

Water Activity

Others

Measuring range     0 … 1 aw

Accuracy              0 … 0.6 ± 0.02

                         0.6 … 0.9 ± 0.04

                         0.9 … 1 ± 0.05

Response time (typical)    < 3 min

Moisture in oil:       0 … 500 ppm

Oil temperature      -40 ... +120 °C

Housing material    316L stainless steel

Weight  :          220 g

Protection Class       IP66

Mechanical connections     G 1/2" ISO or 1/2" NPT

Working temperature   -40 ... +60 °C

Storage temperature     -40 ... +80 °C

Pressure range           Maximum 100 bar

Resistance load            0 … 500 Ω

Supply voltage            DC24V ± 20%    

Cable specification      M8 4 cores, shielded 

Cable length                 2 m

Standard applied           IEC 61010-1

Temperature

Measuring range     -40 ... 80 °C

Accuracy (at +25°C)  ± 0.2 °C

Output 

Digital signal    RS485/RS232

 
 

 

Product Detail Image